[These installation precautions for water-cooled screw chillers have to be seen!]
Release date:[2018/12/21] Is reading[839]次

Water-cooled screw chillers are equipped with advanced control technology. The products have the advantages of high reliability, stable system, high efficiency and energy saving. More than ten kinds of products are available for customers to choose from, which are widely used in chemical, pharmaceutical, plastic, electronic, papermaking. In the laser, electroplating and other industries, it can also be used as a central air conditioner for large-scale supermarkets and offices.


Then, in the daily installation work of water-cooled screw chillers, what should be paid attention to?


1. The water-cooled screw chiller should be installed on a sturdy, level, horizontal reinforced concrete platform or steel platform with sufficient rigidity;


2. The water-cooled screw chiller should have a 160*140*20mm rubber cushion between the platforms, and the spacing between adjacent damping pads should not exceed 1000mm;


3. The maintenance space around the water-cooled screw chiller shall not be less than 1.2m, and the head space shall not be less than 1.5m;


4. The weight of the piping system outside the unit should not be borne by the water-cooled screw chiller water pipe interface. The special support must be stopped to avoid damage to the system due to damage to the sealing components of the unit water pipe;


5, the unit circulating water quality should meet the following requirements: turbidity ≤ 5.0mg / l, ph value 6.5 - 8.5, and should periodically clean the water-cooled screw chiller heat exchanger;


6. Before the water-cooled screw chiller is restarted after the water time is stopped, the waterway valve of the inlet and outlet unit should be closed, and the water system should be cleaned separately until the pipeline system is completely clean. After the water quality meets the conditions, the valve of the inlet and outlet unit can be opened to start the unit. Trial run.