[Whether the compressor is running normally will affect the working efficiency of the industrial chiller]
Release date:[2018/9/14] Is reading[912]次

Industrial chiller compressors do not work, meaning that industrial chillers do not function properly. As the core component of the equipment, the probability of failure of the industrial chiller is very low. In the case of the compressor not operating, it is first necessary to test the auxiliary equipment of the industrial chiller. Checking the compressor while ensuring that the auxiliary equipment is in good condition can reduce the waiting time for the maintenance of the enterprise.


For the failure of the compressor not running, it is necessary to combine the specific state of use of the industrial chiller for testing. If the equipment has just been installed, the compressor will not operate under power-on conditions, and it is also related to the voltage used by the enterprise. Due to the different voltage ranges used by different enterprises, it is necessary to select a suitable industrial chiller for safety, to avoid the problem of voltage inconsistency, etc., which may cause the equipment to be inoperable and affect the normal use of industrial chiller equipment.


After the elimination of the voltage fault, the evaporator and condenser of the equipment need to be tested. Make sure that the entire installation process is completed according to the steps in the installation instructions. If the equipment has been running for a long time, and suddenly the industrial chiller compressor cannot operate, it is necessary to observe whether there is a lot of dust and the like inside the compressor. Due to excessive dust, the internal circuit is short-circuited. The industrial chiller equipment protects itself and will be powered off. Without any energy supply, industrial chillers will not function properly.


Troubleshooting tips


In order to eliminate the failure of the industrial chiller compressor to run faster, it is necessary to carefully judge whether other accessories generate large noise problems during operation. Where are the noises and where they are fully tested. Under the premise of troubleshooting the auxiliary parts, you can check all the lines of the industrial chiller, and carefully judge whether there is a short circuit or the like. Through the above method, the industrial chiller compressor failure can be eliminated in a short time, and the industrial chiller can be resumed. If the equipment with a service life of more than 2 years produces a malfunction that the compressor does not operate, the enterprise needs to be fully maintained for the industrial chiller, so as to prevent such failures from recurring.


The failure of the industrial chiller compressor to operate means that the equipment is not working properly. Enterprises must rely on professionals to complete system inspection and maintenance, restore industrial chillers in a shorter period of time, and reduce the scope of enterprises affected by industrial chiller failures.